Smart Home Gas Meter Fast-Closing Cut-off Valve

Model No.: RKF-4

Short Description:

The electronically controlled stop valve is a valve installed at the air inlet or outlet of the smart gas meter and is used to control the on and off of gas. Adopting a unique appearance design, the valve body is small and has strong adaptability to the base meter. It can be assembled on gas meters of various specifications. In addition, it has the characteristics of low cost and small pressure loss.


Product Detail

Product Tags

Installation Location

The motor valve may be installed in the smart gas meter.

valve installation

Product Advantages

Built-in screw Motor Valve’s Advantages
1.Low pressure drop
2.Stable structure Max pressure can reach 150mbar
3.Small shape, easy installing
4.Customizable

Instruction For Use

1.This type of valve has two lead wires to supply power to the valve. The red wire is connected to positive power (or negative power), and the black wire is connected to negative power (or positive power) to open the valve (specifically, it can be set according to customer needs).
2.The minimum drive voltage of the valve shall not be lower than 3V. If the current limit design is in the process of opening and closing the valve, the current limit value shall not be lower than 130mA
3.The motor valve opening and closing can be judged by detecting the locked-rotor current in the circuit. The locked-rotor current value can be calculated according to the working cut-off voltage of the circuit design, which is only related to the voltage and resistance value.

Tech Specs

Items requirements Standard

Working medium

Natural gas,LPG

Flow range

0.016~6m3/h

Pressure Drop

0~15KPa

Meter suit

G1.6/G2.5/G4

Operating voltage

DC3~3.9V

ATEX

ExicⅡBT4 Gc

EN 16314-2013 7.13.4.3

Operating temperature

-25℃~60℃

EN 16314-2013 7.13.4.7

Relative humidity

5%~90%

Leakage

2KPa or 7.5ka <1L/h

EN 16314-2013 7.13.4.5

Motor electric performance

21±10%Ω/14±2mH

Current-limited resistance

9±1%Ω

Max current

≤140mA(DC3.9V)

opening time

≤0.8s(DC3V)

Closing time

≤0.8s(DC3V)

Pressure loss

With meter case≤200Pa

EN 16314-2013 7.13.4.4

endurance

≥10000次

EN 16314-2013 7.13.4.8

Installation location

Inlet/Outlet