Chinese Professional Brass Ball Valve with ISO 228/1 Thread
With our rich working experience and thoughtful companies, we have now been recognized as being a trustworthy supplier for a lot of global potential buyers for Chinese Professional Brass Ball Valve with ISO 228/1 Thread, Welcome your enquiry, most effective service will likely be provided with full heart.
With our rich working experience and thoughtful companies, we have now been recognized as being a trustworthy supplier for a lot of global potential buyers for China Ball Valve and Brass Ball Valve, we’re sincerely hope to establish one good long term business relationship with your esteemed company thought this opportunity, based on equal, mutual beneficial and win win business from now till the future.
Installation location
The motor valve may be installed in the smart gas meter.
Product Advantages
Built-in B& Motor Valve’s Advantages
1.Low pressure drop
2.Stable structure Max pressure can reach 200mbar
3.Small shape, easy installing
4.Low costs
Instruction For Use
1. The lead wire of this type of valve has three specifications: two-wire, four-wire or six-wire. The lead wire of the two-wire valve is only used as the valve action power line, the red wire is connected to positive (or negative), and the black wire is connected to negative (or positive) to open the valve (specifically, it can be set according to customer requierements). For four-wire and six-wir e valves, two of the wires (red and black) are the power supply wires for valve action, and the remaining two or four wires are status switch wires, which are used as signal output wires for open and closed positions.
2. Power supply time requirements: when opening/closing valve, after the detection device detects that the valve is in place, it needs to delay 2000ms before stopping the power supply, and the total operating time is about 4.5s.
3. The motor valve opening and closing can be judged by detecting the locked-rotor current in the circuit. The locked-rotor current value can be calculated according to the working cut-off voltage of the circuit design, which is only related to the voltage and resistance value.
4. It is recommended that the minimum DC voltage of the valve should not be less than 3V. If the current limit design is in the valve’s process of opening and closing, the current limit value should not be less than 120mA.
Tech Specs
Items | requirements | Standard |
Working medium |
Natural gas,LPG |
|
Flow range |
0.016~6m3/h |
|
Pressure Drop |
0~20KPa |
|
Meter suit |
G6/G10/G16/G25 |
|
Operating voltage |
DC3~3.9V |
|
ATEX |
ExicⅡBT4 Gc |
EN 16314-2013 7.13.4.3 |
Operating temperature |
-25℃~60℃ |
EN 16314-2013 7.13.4.7 |
Relative humidity |
5%~90% |
|
Leakage |
2KPa or 7.5ka <1L/h |
EN 16314-2013 7.13.4.5 |
Motor electric performance |
20±10%Ω/16±2mH |
|
Current-limited resistance |
12±1%Ω |
|
Max current |
≤130mA(DC3.9V) |
|
opening time |
≤4.5s(DC3V) |
|
Closing time |
≤4.5s(DC3V) |
|
Pressure loss |
With meter case≤200Pa |
EN 16314-2013 7.13.4.4 |
endurance |
≥10000 times |
EN 16314-2013 7.13.4.8 |
Installation location |
Inlet/outlet |
With our rich working experience and thoughtful companies, we have now been recognized as being a trustworthy supplier for a lot of global potential buyers for Chinese Professional Brass Ball Valve with ISO 228/1 Thread, Welcome your enquiry, most effective service will likely be provided with full heart.
Chinese Professional China Ball Valve and Brass Ball Valve, we’re sincerely hope to establish one good long term business relationship with your esteemed company thought this opportunity, based on equal, mutual beneficial and win win business from now till the future.