Aluminum Self-closing Safety Valve with Sealing Ring

Model No.: GDF-2

Short Description:

Pipeline gas self-closing valve refers to the device installed on the indoor gas pipeline, which has the functions of overpressure automatic closing, undervoltage automatic closing, and overcurrent automatic closing. It does not use external power when closing and must be manually opened after closing. Close the valve. The self-closing valve can sense changes in gas pressure and flow. When it exceeds the safe range, it can automatically close. It needs manual reset. It does not require electricity or any external power. It is sensitive and reliable, and the cut-off time is less than 3 seconds. The gas source is cut off from the initial stage of the accident. , to prevent further expansion of the accident.


Product Detail

Product Tags

Installation Location

The self-closing valve can be installed on the gas pipeline in front of the stove or water heater.

product (2)

Product Advantages

Pipeline self-close safety Valve’s feature and advantages

1. Reliable sealing

2. High sensitivity

3. Quick response

4. Small size

5. No energy consumption

6. Easy to install and use

7. Long service life

Function Introduction

Overpressure automatic shutdown

When the pressure regulator at the front end of the gas pipeline works abnormally or the pipeline pressure is too high due to the pipeline pressure test conducted by the gas company, and exceeds the overpressure setting value of the pipeline gas self-closing valve, the valve will automatically close due to the overpressure to prevent the overpressure caused by the pipeline pressure. Excessively high and gas leakage occurs.

Underpressure automatic shutdown

When the pressure regulator at the front end of the gas pipeline is abnormal, during the peak period of gas consumption, the gas pipeline is frozen and blocked, gas shortage in winter, gas shutdown, replacement, decompression and other operations cause the pipeline pressure to drop and fall below the set value, The valve will automatically close under pressure to prevent gas leakage accidents that may occur when the air pressure is restored.

Overflow automatic shutdown

When the gas source switch and the front-end pressure regulator of the gas pipeline are abnormal, or the rubber hose falls off, ages, ruptures, the aluminum-plastic pipe and metal hose are perforated by electric corrosion, cracks appear in stress changes, the connection is loose, and the gas stove is abnormal, etc., When the gas flow in the pipeline overflows for a long time and exceeds the set value of the overcurrent flow of the valve, the valve will automatically close due to overcurrent, interrupting the gas supply, and preventing possible safety accidents caused by excessive gas outflow.

Instruction For Use

1691395743464

Valve initial closed state

1691395754566

Normal working state

1691395762283

Undervoltage or overcurrent self-shutdown

1691395769832

overpressure self-shutdown

1. In the normal air supply state, gently lift up the valve lifting button (just lift it up gently, do not use too much force), the valve will open, and the lifting button will automatically reset after releasing it. If the lifting button cannot be reset automatically, please manually press the lifting button to reset.

2. The normal working state of the valve is shown in the figure. If it is necessary to interrupt the gas supply of the gas appliance during use, it is only necessary to close the manual valve at the outlet end of the valve. It is strictly forbidden to press the indicator module by hand to directly close the valve.

3. If the indicator module drops and closes the valve during use, it means that the valve has entered an undervoltage or overcurrent self-closing state (as shown in the figure). Users can check themselves by the following reasons. For problems that cannot be resolved by themselves, they must be resolved by the gas company. Do not solve it by yourself, the possible reasons are as follows:

(1) The gas supply is interrupted or the pipeline pressure is too low;

(2) The gas company stops gas due to equipment maintenance;

(3) Outdoor pipelines are damaged by man-made and natural disasters;

(4) Others in the room The emergency shut-off valve is closed due to abnormal conditions;

(5) The rubber hose falls off or the gas appliance is abnormal (such as gas leakage caused by an abnormal switch);

4. During use, if the indicator module is found to rise to the highest position, it means that the valve is in an overpressure self-closing state (as shown in the figure). Users can conduct self-inspection through the following reasons and solve them through the gas company. Do not solve it by yourself. After troubleshooting, press the indicator module to restore the valve to the initial closed state, and lift the valve lift button again to open the valve. Possible causes of overpressure autism include the following:

(1) The front end pressure regulator of the gas pipeline is not working properly;

(2) The gas company conducts pipeline operations. Excessive pipeline pressure due to pressure testing;

5. During use, if you accidentally touch the indicator module, causing the valve to close, you need to lift the button to reopen the valve.

Tech Specs

Items Performance Reference Standard
Working medium Natural gas,Coal gas
Rated Flow 0.7 m³/h 1.0 m³/h 2.0 m³/h CJ/T 447-2014
Operating pressure 2kPa
Operating temperature -10℃~+40℃
Storage temperature -25℃~+55℃
Humidity 5%~90%
Leakage 15KPa detection 1min ≤20mL/h CJ/T 447-2014
Closing time ≤3s
Overpressure self-closing pressure 8±2kPa CJ/T 447-2014
Underpressure self-closing pressure 0.8±0.2kPa CJ/T 447-2014
Overflow self-closing flow 1.4m³/h 2.0m³/h 4.0m³/h CJ/T 447-2014
1691394174972