6 Wires Industrial Smart Prepaid Gas Meter Valve
Installation Location
Product Advantages
Built-in B& Motor Valve’s Advantages
1.Good sealing, and low pressure drop
2.Stable structure Max pressure can reach 200mbar
3.Small shape, easy installing
4. Compatible with many types of gas meter
Instruction For Use
1. The lead wire of this type of valve has three specifications: two-wire, four-wire or six-wire. The lead wire of the two-wire valve is only used as the valve action power line, the red wire is connected to positive (or negative), and the black wire is connected to negative (or positive) to open the valve (specifically, it can be set according to customer requirements). For four-wire and six-wire valves, two of the wires (red and black) are the power supply wires for valve action, and the remaining two or four wires are status switch wires, which are used as signal output wires for open and closed positions.
2. Power supply time requirements: when opening/closing valve, after the detection device detects that the valve is in place, it needs to delay 2000ms before stopping the power supply, and the total operating time is about 4.5s.
3. The motor valve opening and closing can be judged by detecting the locked-rotor current in the circuit. The locked-rotor current value can be calculated according to the working cut-off voltage of the circuit design, which is only related to the voltage and resistance value.
4. It is recommended that the minimum DC voltage of the valve should not be less than 3V. If the current limit design is in the valve’s process of opening and closing, the current limit value should not be less than 120mA.
Tech Specs
Items | requirements | Standard |
Working medium |
Natural gas,LPG |
|
Flow range |
0.1~40m3/h |
|
Pressure Drop |
0~50KPa |
|
Meter suit |
G10/G16/G25 |
|
Operating voltage |
DC3~6V |
|
ATEX |
ExibⅡBT3 Gb
|
EN 16314-2013 7.13.4.3 |
Operating temperature |
-25℃~55℃ |
EN 16314-2013 7.13.4.7 |
Relative humidity |
≤90%
|
|
Leakage |
Leakage ≤0.55dm ≤ 30KPa |
EN 16314-2013 7.13.4.5 |
Motor resistance |
20Ω±1.5Ω |
|
Motor inductance |
18±1.5mH |
|
Open valve average current |
≤60mA(DC3V) |
|
Blocked current |
≤300mA(DC6V) |
|
Opening &closing time |
≈4.5s(DC3V) |
|
Pressure loss |
≤ 375Pa(with valve base gauge pressure loss ) |
EN 16314-2013 7.13.4.4 |
Endurance |
≥10000 times |
EN 16314-2013 7.13.4.8 |
Installation location |
Inlet |