12

product

2/4/5 Wire Small Household Gas Meter Motor Shut-off Valve

Model No.: RKF-4 Ⅱ

Short Description:

RKF-4Ⅱ type valve is installed on the gas meter to control the gas switch. The buckle design is adopted without using screws, which greatly improves the corrosion resistance. The product is small in size, the switching time is less than 1 second, and it is compatible with various specifications of gas meters. It also has the characteristics of low cost and small pressure loss. In addition, the valve is available with 2 leads, 4 leads, 5 leads, or we can customize the valve according to your gas meter.


Product Detail

Product Tags

Installation Location

The motor valve may be installed in the smart gas meter.

Valve installation

Product Advantages:

Built-in screw Motor Valve’s Advantages
1.Low pressure drop
2.Stable structure Max pressure can reach 200mbar
3.Small shape, easy installing
4.Low costs
5.Snap design with high rust resistance

Instruction For Use

1.Two-line, four-line and five-line models are available for this type of valve. The red wire is connected to positive power (or negative power), and the black wire is connected to negative power (or positive power) to open the valve (specifically, it can be set according to customer needs). The other 2 or 3 wires can be signal wires of open/close.
2.Four-wire or five-wire valve opening and closing process time setting: When opening and closing the valve, when the detection device detects that the opening or closing valve is in place, it needs to delay 300ms before stopping the power supply, and the total time of opening the valve is about 1s.
3.The minimum drive voltage of the valve shall not be lower than 3V. If the current limit design is in the process of opening and closing the valve, the current limit value shall not be lower than 120mA
4.The motor valve opening and closing can be judged by detecting the locked-rotor current in the circuit. The locked-rotor current value can be calculated according to the working cut-off voltage of the circuit design, which is only related to the voltage and resistance value.

Tech Specs

Items requirements Standard

Working medium

Natural gas,LPG

Flow range

0.016~6m3/h

Pressure Drop

0~15KPa

Meter suit

G1.6/G2.5

Operating voltage

DC3~3.9V

ATEX

ExicⅡBT4 Gc

EN 16314-2013 7.13.4.3

Operating temperature

-25℃~60℃

EN 16314-2013 7.13.4.7

Relative humidity

5%~90%

Leakage

2KPa or 7.5ka <1L/h

EN 16314-2013 7.13.4.5

Motor electric performance

21±10%Ω/14±2mH

Current-limited resistance

9±1%Ω

Max current

≤140mA(DC3.9V)

opening time

≤1s(DC3V)

Closing time

≤1s(DC3V)

Pressure loss

With meter case≤200Pa

EN 16314-2013 7.13.4.4

endurance

≥10000次

EN 16314-2013 7.13.4.8

Installation location

Inlet


  • Previous:
  • Next: